Abstract
Complete blood count (CBC) is the most commonly ordered investigation. It is most versatile yet most economical. CBC can be done by manual or automated method. This study evaluates the performance of two automated cell counters for the analysis of CBC. The main purpose of the study is to evaluate hematological parameters in various hematological disorders and to discuss the advantages, disadvantages of both instruments in relation with diagnosis of common hematological disorders. This prospective study was carried out at department of pathology in tertiary care hospital over the period of 2 years. Blood samples from 100 patients of age 13 years and above was collected into K3EDTA tube, and analyzed using both counters. The common hematological parameters between two counters were compared by using kappa test and then categorized into below normal, normal and above normal. The results were given in the form of strength of agreement (very good, good, fair and poor). Good to fair correlation were found for almost all parameters. However, MCV was underestimated by mythic 3part counter. The blood samples having too high and too low TLC were recognized only by sysmex. Thus this study concludes that, 5 part cell counter is technically more advanced with methodological superiority but 3part hematology analyzer is cost effective.
Keywords: Automated cell counter, hematology analyzer, CBC.
References
- Greer JP, Daniel AA, Alan FL, Forester J, Rodgers GM. Wintrobe Clinical Haematology, 13th edition, Wolters Kluwer, Lippincott Williams and Wilkins Health, 2014.
- Frank F, Chesterman C, Penington D, Rush B. de Gruchy’s Clinical Haematology in Medical Practice. 5th edition,Wiley.1991.
- Bain B,Lewis S, Dacie J. Dacie and lewis practical haematology.12th Churchill livingstone:Elesevier;2017.
- Pekelharing JM, Hauss O, Jonge R, Lokhoff J, Sodikromo J , Spaans M et al. Haematology reference intervals for established and novel parameters in healthy adults.Diagnostic Perspectives. The Sysmex Europe Journal for Clinical Laboratory Medicine. Kobe Japan. 2010;1:01-11. Avalaible from www.sysmex-europe.com published on 2010.
- Briggs C. Quality counts: new parameters in blood cell counting. International Journal of Laboratory Hematology. 2009;31:277–297.
- Bain B J., Lewis S M., Bates I. Basic haematological techniques. In:Lewis S M, Bain B J, Bates I. Dacie and Lewis Practical Haematology. 10th India. Published by Elsevier;2006:41-43.
- Buttarello M, Plebani M. Automated Blood Cell Counts, State of the Art.Am J Clin Pathol. 2008;130:104-116.
- Mythic 18 Orphee SA. Cod.M18/UM-EN/001, Switzerland. Available from http://www.orphee-medical.com
- Sysmex Automated Hematology Analyzer XS series-XS1000i /XS800i. Instructions for use. Sysmex corporation Kobe, Japan. April 2009. Available from http://www.sysmex-europe.com
- Perkins SL. Examination of the Blood and Bone Marrow. In: Greer J.P., Foerster J., Rodgers G. M., Paraskevas F., Glader B., Arber D.A.,Means R.T.Eds.Wintrobes Clinical Hematology.12th Edition. Lippincott Williams and Wilkins; 2008:1-5.
- Bruegel M, Nagel D, Funk M, Fuhrmann P, Zander J, Teupser D.Comparison of five automated hematology analyzers in a university hospital setting: Abbott Cell-Dyn Sapphire, Beckman Coulter DxH 800,Siemens Advia 2120i, Sysmex XE-5000 and Sysmex XN-2000. Clin Chem Lab Med.2015 Jun;53(7):1057-71
- Meintker L, Ringwald J, Rauh M, Krause SW. Comparison of automated differential blood cell counts from Abbott Sapphire, Siemens Advia 120, Beckman Coulter DxH 800, and Sysmex XE-2100 in normal and pathologic samples. Am J Clin Pathol.2013 may;139(5):641-650.
- Buoro S , Mecca T, Seghezzi M, Manenti B, Azzara G, Dominoni P, Crippa A et al. Analytical comparison between two hematology analyzer systems: CAL-8000 vs. XN-9000.
Corresponding Author
Dr Amruta Shankar Jujgar
Department of Pathology, Government Medical College, Aurangabad, Maharashtra, India
Contact no. 8149334616; Email: This email address is being protected from spambots. You need JavaScript enabled to view it.