Abstract
Aim: Possibility of encountering difficulty at intubation canotbe ruled out at every preanesthetic evaluation. The present study was aimed to compare the intubation difficulty scale for macintosh and truview laryngoscope blades in elective surgical patients which were deemed to have normal airway assessment.
Methods: Sixty patients of ASA I/II with normal airway based on certain parameters were divided in two groups A and B. A were intubated with macintosh and B with Truview blade.
Laryngeal view was assessed by Cormack Lehane grades and percentage of gottis opening score. The intubation difficulty was assessed based upon seven variables of Intubation Difficulty Scale (IDS) and compared between the two groups. IDS was primary while POGO and CL score were secondary outcome. The two groups were statistically evaluated by applying unpaired t test for parametric data and chi square test for categorical data. P<0.05 was significant.
Results: Cormack and Lehane grade 1 in 22 patients (73.3%) for group A and 27 patients (90%) in group B were recorded. The mean IDS for group A and B was 1.30±0.92 and 0.20±0.50 respectively.
Conclusions: Evaluation of airway can be assumed to complete at pre anaesthetic check up. There are multiple factors which can influence the outcome of intubation difficulty scale. One such can be the design of the blade.
Keywords: Intubation difficulty scale(IDS), Percentage of glottis opening(POGO)score and Cormack and Lehane grades(CL grade)
References
- Hochman II, Zietels SM, Heaton JT. Analysis of the forces and position required for direct exposure of the anterior vocal cords. Ann Otol Rhinol Laryngol 1999;108:715-24.
- Zietels SM, Burns JA, Dailey SH. Suspension laryngoscopy revisited. Ann Otol Rhinol Laryngol 2004;113: 16-22.
- Beckmann LA, Edwards MJ, Greenalnd KB. Differences in two rigid indirect laryngoscopes- letter. Anaesthesia 2008;63 :1385-86.
- Friedrich g, Gugatschka. Influence of head positioning on the forces occurring during microlaryngoscopy. European archieves of Oto-Rhino-Laryngology2009;266:999-1003.
- Iohom G, Ronayne M, Cunningham AJ: Prediction of difficult airway intubation, Eur J Anaesthesiol 2003; 20:31-36, .
- Merah NA, Wong DT, Ffoulkes-Crabbe DJ, Kushimo OT, Bode CO: Modified Mallampati test, thyromental distance gap are the best predictors of difficult laryngoscopy in west afericans, Can J Anaesth 2005;52:291-296.
- Wilson ME, Spiegelhalter D, Robertson JA, Lesser P: Predicting difficult intubation, Br J Anaesth 1988; 61:211-16.
- El-Ganzouri AR, Mccarthy RJ, Tuman KJ, Tanck EN, Ivankovich AD: Preoperative airway assessment: Predictive value of a multivariate risk index, Anesth Analg 1996; 82:1197-1204.
- Cormack RS and Lehane J. Difficult tracheal intubation on obstetrics Anaesthesia, 1984; 39:pp 1105-11.
- Bhandari G, Shahi KS, Asad M, Bhakuni R. Airtraq versus Macintosh laryngoscope. A comparative study in tracheal intubation. Anaesthesia essays and researches 2013;7:232-6.
- Adnet f et al. The intubation difficulty scale(IDS). Proposal and evaluation of a new score characterizing the complexity of endotracheal intubation Anaesthesiology, 1997;87(6): pp759-62.
- Kolli S, Karnik S, Parikh A, Tendolkar A. A comparative evaluation of Truviewamd Macintosh laryngoscope for tracheal intubation. Bombay Hospital Journal 2015;57:297-305.
- Kulkarni A, Tirmanwar A. Comparison of glottis visualization and ease of intubation with different laryngoscope blades. Indian J Anaesth 2013;57:170-3.
- Ochroch EA, Hollander JE, Kush H, Shofer FS, Levitan RM. Assessment of laryngeal view: percentage of glottic opening score vsCornack and Lehane grading. Can J Anaesth 1999;46:987-90.
- Bharti N, Arora S, Panda NB. A comparison of McCoy, TruView, and Macintosh laryngoscopes for tracheal intubation in patients with immobilized cervical spine. Saudi J Anaesth2014;8: 188–192.
- Dwivedi Y, Shukla V, Shrivastav U compared Airtraq and Truview with Macintosh Laryngoscope for endotracheal intubation : A controlled clinical trial Journal of Anaesthesia and critical care : open access 2015;3:1-6.
- Saxena A, Madan M, Shrivastava U, Mittal A, Dwivedi Y, Agrawal A, Puri R. Role of the Truview EVO2 laryngoscope in the airway management of elective surgical patients: A comparison with the Macintosh laryngoscope. Indian J Anaesth 2013;57:276-81
Corresponding Author
Dr (Prof). Deepak Sharma
Mobile No.: +91-9457231609, Email: This email address is being protected from spambots. You need JavaScript enabled to view it.