Abstract
Background: Measurement of Central Venous Pressure (CVP) serves as an important hemodynamic monitor in major surgical procedures associated with blood loss and extensive fluid administration. In order to combat the risks associated with this highly invasive method, the peripheral venous pressure measurement as a trend monitor like central venous pressure measurement was introduced. Since the procedural complications and technical complications are less with peripheral venous pressure measurement it is emerging as a hemodynamic monitor in major neurosurgical procedures. Requirement of USS and highly qualified personnel not necessary for PVP measurement unlike central Venous Cannula insertion.
Materials and Method: In this study 25 patients posted for major neurosurgical procedures, peripheral venous catheter was connected to a pressure transducer which was linked to multichannel monitor and the peripheral venous pressure trends are recorded every 15 minutes. AS CVP measurement is stipulated as standard hemodynamic measurement as per text books for neurosurgical procedures in parallel to PVP, CVP was also measured.
Results: peripheral venous pressure recording serially done showed the trends in hemodynamics in various stages of surgery. Initial period of surgery showed lower, values trend due to induction and subsequent use of the mannital and diuretics. After correction of decreased trends in PVP gradual increase was showed in peripheral venous pressure. Peripheral venous pressure remained as higher value compared to the central venous pressure.
Conclusion: Peripheral venous pressure can be used as a monitor for hemodynamic trends in major neurosurgical procedures and as a guide for intra operative fluid therapy. CVP can also be predicted from PVP. But PVP can’t be used for aspiration of air embolism from heart clambers unlike central venous catheter.
Keywords: CVP- Central Venous Pressure, PVP- Peripheral venous pressure, USS_ Ultra sound scan.
References
- Munis R., Bhatia S, Lozada LJ, Peripheral venous pressure as a haemodynamic variable in Neurosurgical patients Anesthesia and Anagesia 2001; 172-9
- Folkow B, Mellander S., veins and venous tone. AM heart J, 1964; 68-397- 408.
- Choi SJ, Gwak MS, Ko JS otal. Can peripheral venous pressure be an alternative to central venous pressure during right hepatectomy in living donor? Liver transplant 2007; 13:1414-1421.
- Hoftman N, Braunfeld, Hofman G, Melajo A peripheral venous pressure as a predictor of central venous pressure during orthoptic liver transplantation JClin Anaesth 2006, 18: 251-255
- Milohan KA lovy DJ, Shields N, Rothman A. upper extremity peripheral venous pressure measurements accurately reflect pulmonary artery pressures in patients with cavopulmonary or fontan connections podiatri cardio 2004; 25: 17-19
- Tobias JD, Johnson JO, Measurement of central venous pressure from a peripheral vein infants and children pediatric emerg care 2003; 19: 428 – 430
- Desjarding R, Denault Ay Belisle s et al can periopheral venous pressure be interchangeable with central venous pressure in patients undergoing cardiac surgery? Intensive care med 2004; 30:627-632
- Peripheral venous pressure as measure of venous compliance during phacocytoma rejection. Weingarten, Toby NMP; Sprung Juray MD, PhD, munis, Jamas, RMD, PhD. Anaesthetic and Analgesia October 2004 volume 99 Issue 4-P 1035 – 1037.
- Peripheral venous pressure as hemodynamic variable in neurosurgical patients. Munis Bhattatia S, Lozada LJ
- Peripheral venous pressure as a reliable predictor for monitoring central venous pressure in patients with burns. Lulu Sherif, Vikas S Joshi, Anjali Olappally, Prithi Jain, Kishan shetty, Karl Sa Ribero Dept. of Anaesthesiology for mullur Medical Colelge Mangalore Karnataka India 2015 / Volume 19/issue: 4 / page 199-202
- D Melendez JA, Zhang H, Dobresn C, Leung DH, Padilla correlation of peripheral venous pressure e and control venous pressure in surgical patients J cardiothoracic vasc Anaesth 2001,15:40-3
- Anter AM, Bobdok BS peripheral venous pressure is an alternative to central venous pressure in pediatric surgery patients, Acta Anaesthesil, Scand 2004; 48: 1101 – 4
- Sabarin A, Salman MA, Salman AE, Ayser effect of catheter site on the agreement of peripheral and central venous pressure measurement in neurosurgical patients. J clinic Anaesth 2005, 17: 348-52
- Amoozgar H, Ajani GH, Borzuce M, Amirghofran AA, Ebrahimi P Peripheral vascular Pressure as a predicoptr of CVP in continuous monitoring in children. Iran Red cresemnt med J 2011; 13: 342 -5
Corresponding Author
Dr C. Jayakumar
Associate Professor, Department of Anesthesiology, Government Medical College, Trivandrum, India