Abstract
This paper presents the designing of real time ECG signal conditioning circuit. For designing the real time ECG signal conditioning circuit need to understand the physiology of heart. For analysis the heart activity a instrument is used, called as Electrocardiogram(ECG). It is widely used for diagnosis of heart diseases. ECG recorded in 12 lead configuration using 10 electrode placed on the human body. This recordings are often corrupted by motion artifacts, power-line interferences and other noises. The corrupted signal leads to misinterpretation of data, which in turn causes very serious consequences as it leads to misdiagnoses of dangerous disease. Hence the artifacts need to be suppressed by using the appropriate methods and a conditioned signal is obtained. In this paper proposed a designed and tested circuit on hardware and software to extract the real time ECG signal from the subject, This circuit also suppressed the artifacts present in the ECG signal.
Keywords—ECG, heart, noise, artifacts etc.
References
1. Husna, Mohammadi, Iram L. et al. “Design and Implementation of ECG Monitoring and Heart Rate Measurement System ”, IJESIT Volume 2, Issue 3, May 2013
2. G. Eason, B. Noble, and I.N. Sneddon, “On certain integrals of Lipschitz-Hankel type involving products of Bessel functions,” Phil. Trans. Roy. Soc. London, vol. A247, pp. 529-551, April 1955. (references)
3. Braunwald E. (Editor), Heart Disease: A Textbook of Cardiovascular Medicine, Fifth Edition, p. 108, Philadelphia, W.B. Saunders Co., 1997. ISBN 0-7216-5666-8.
4. Van Mieghem, C; Sabbe, M; Knockaert, D (2004). "The clinical value of the ECG in no cardiac conditions” Chest 125(4):1561–76.Doi:10.1378/chest.125.4.1561.PMID 15078775.
5. "2005 American Heart Association Guidelines for Cardiopulmonary Resusc-itation and Emergency Cardiovascular Care - Part 8: Stabilization of the Patient With Acute Coronary Syndromes." Circulation 2005; 112: IV-89-IV-110.
6. R. Houghton and D. Gray., “Making sense of the ECG”., Hodder Arnold Publishing’s 2003.
7. Forerunner 201/301 User Guide, web site: http://www.grmin.com.
8. Pulsar heart rate monitors, web site: http://www.heartratemonitor.co.uk.
9. David A. Bell, “Operational amplifiers and linear ICs”, 2nd Edition, Oxford University Press, 1997
10. Nagendra H et al. “Application of Wavelet Techniques in ECG Signal Processing: An Overview ” International Journal of Engineering Science and Technology (IJEST)
Corresponding Author
Ms Pushpa Gothwal
Assistant Professor, ECE Department (ASET),
Amity University, Rajasthan (AUR) Jaipur, India
Email: This email address is being protected from spambots. You need JavaScript enabled to view it.