Title: Role of High Resolution Ultrasonography and Guided Fine Needle Aspiration Cytology in the Evaluation of Patients with Thyroid Swellings

Authors: Dr Rajmohan J L, Dr Minimol  K L, Dr Nizarudeen A

 DOI:  https://dx.doi.org/10.18535/jmscr/v5i3.118

Abstract

Introduction: Thyroid swellings constitute a major proportion of neck swellings. Approach to the management of solitary and multinodular thyroid differs, and conservative management is considered to be the preferred treatment option.  The utilization of high-frequency ultrasound to augment clinical diagnosis would be helpful in avoiding unnecessary thyroidectomy in a patient presented with nodular thyroid disease.

Materials and Method: This study was carried out in the department of surgery, Medical College, Trivandrum during 2009 to 2012. We evaluated the role of high resolution ultrasound and FNAC in thyroid swelling in 50 patients. Sensitivity, specificity, true positive predictive value and negative predictive value and accuracy of sonological findings compared to FNAC findings were calculated.

Results: There was a female predominance with male to female ratio of 1:9. Although clinical evaluation showed most of the cases as solitary nodules, sonological examination and fine needle aspiration cytology proved that the most common type was multinodular goiter followed by adenoma . In the present study sonological diagnosis failed to identify malignancy in all cases but was proven by FNAC.

Discussion: Major challenges faced by a clinician in management of thyroid swelling is, whether the nodule is benign or malignant and whether management need to be conservative or surgical. In our study group, a marked discrepancy was found between palpatory findings of solitary nodule and sonographic findings. There was also a marked discrepancy between palpatory finding of diffuse enlargement and sonographic findings. Multi nodulargoitre was found to be the most common abnormality.  Although 24 patients were diagnosed as having solitary nodule on clinical evaluation ultrasonography showed 14 had solitary nodule while 10 patients had multiple nodules. Out of all 7 cases categorized as malignant in FNAC, all were reported as benign in ultrasound.

References

1.      Unnikrishnan AG, Menon UV. Thyroid disorders in India: An epidemiological perspective. Indian journal of endocri-nology and metabolism. 2011;15(Suppl2): S78-S81.

2.      Brander A, Viikinkoski P, Tuuhea J, Voutilainen L, Kivisaari L. Clinical versus ultrasound examination of the thyroid gland in common clinical practice. Journal of Clinical Ultrasound. 1992;20(1):37-42.

3.      Cole-Beuglet C, Goldberg BB. New high-resolution ultrasound evaluation of diseases of the thyroid gland: A review article. JAMA : the journal of the American Medical Association. 1983;249 (21):2941-4.

4.      Solbiati L, Volterrani L, Rizzatto G, Bazzocchi M, Busilacci P, Candiani F, et al. The thyroid gland with low uptake lesions: evaluation by ultrasound. Radiology. 1985;155(1):187-91.

5.      Butch RJ, Simeone JF, Mueller PR. Thyroid and parathyroid ultrasonography. Radiologic clinics of North America. 1985;23(1):57-71.

6.      Xie C, Cox P, Taylor N, LaPorte S. Ultrasonography of thyroid nodules: a pictorial review. Insights into Imaging. 2016;7(1):77-86.

7.      Tunbridge WM, Evered DC, Hall R, Appleton D, Brewis M, Clark F, et al. The spectrum of thyroid disease in a community: the Whickham survey. Clinical endocrinology. 1977;7(6):481-93.

8.      Vander JB, Gaston EA, Dawber TR. Significance of solitary nontoxic thyroid nodules; preliminary report. The New England journal of medicine. 1954; 251 (24):970-3.

9.      Filetti S, Durante C, Torlontano M. Nonsurgical approaches to the manage-ment of thyroid nodules. Nat Clin Pract End Met. 2006;2(7):384-94.

10.  Burch HB. Evaluation and management of the solid thyroid nodule. Endocrinology and metabolism clinics of North America. 1995;24(4):663-710.

11.  Brander A, Viikinkoski P, Tuuhea J, Voutilainen L, Kivisaari L. Clinical versus ultrasound examination of the thyroid gland in common clinical practice. J Clin Ultrasound. 1992;20(1):37-42.

12.  Knudsen N, Bols B, Bulow I, Jorgensen T, Perrild H, Ovesen L, et al. Validation of ultrasonography of the thyroid gland for epidemiological purposes. Thyroid. 1999;9 (11):1069-74.

13.  Scheible W, Leopold GR, Woo VL, Gosink BB. High-resolution real-time ultrasonography of thyroid nodules. Radiology. 1979;133(2):413-7.

Corresponding Author

Dr Rajmohan J L

Divine Gardens, Kanakanagar, House No A143 (b)

Kowdiar P O, Thiruvananthapuram- 695003, Kerala, India

Email: This email address is being protected from spambots. You need JavaScript enabled to view it.