Title: To Compare the Dose of Propofol for Induction of Anaesthesia by Entropy Monitoring against Standard Induction dose in Elderly Patients

Authors: Dr Mohamed Zuhail  K.P, Dr Madhusoodanan Pillai.C

 DOI:  https://dx.doi.org/10.18535/jmscr/v5i3.42

Abstract

Background: Entropy monitoring is a new method for measuring depth of anaesthesia and degree of hypnosis. Two parameters are displayed in the monitor -State entropy (SE) and Response entropy (RE). Aging lead to decrease clearance of propofol. Hence when recommended induction dose of propofol (mg/kg ) is  used it may lead to haemodynamicinst ability especially in elderly patients. Little information is available regarding the use of EEG entropy in the prevention of   adverse hamodynamic side effects during induction of anaesthesia with propofol in elderly patients.

Aim: To compare the dose requirement of propofol in induction of anaesthesia with the end points indicated by entropy value verus recommended induction dose in elderly patients .

Methodology: This was aquasi - experimental open trial conducted in the department of anesthesiology, Government   Medical college, Thiruvananthapuram, a tertiary care centre, A total of 120 patients above 60 years of ASA  class I and  II were enrolled in the study. Enrolled patients were allotted to test group and control group randomly. Propofol was used for induction of anaesthesia in both groups and these groups were monitored with continuous electrocardiography, noninvasive blood pressure, pulse oximetry and capnography. In the test group depth of anaesthesia was monitored with entropy where the end point of induction was RE 50 and SE- RE difference less tha 10.Recommended dose of propofol was administered to the control group. Haemodynamic parameters during induction and intubation -were monitored along with entropy monitoring in both groups .Statistical tests used were Chi-square, student‘ t test and Mann-Whitney U test .

Results: -The total induction dose of Propofol and dose /kg were significantly reduced by 20% and 25% respectively in the entropy group and adequate haemodynamic stability was maintained.

Conclusion: The use of EEG entropy during induction of anaesthesia in elderly patients reduces propofol requirements and maintains cardiovascular stability.

Keywords: induction ofanaesthesia, propofol, entropy.

References

1.      Task Force. 2006. Practice advisory for intraoperative awareness and brain function monitoring. Anesthesiology 104, no. 4, pages 847-864.

2.      Liju.J, Sin.H, White PF,. Electroenceph-alographic bispectral index coreleates with intraoperative recall and depth of propofol induced sedation. Anaesthesia Analgesia 1997.84 185-9.

3.      Choi SR, Chung CJ , Park Sw >Lee SI. A comparison of bispectral index and spec-tral entropy during sevoflurane anaesthe-sia.

4.      Bruhn, LE Lehmann, H ropke ,Tw Boullion, A Hoeft, Shannon Entropy applied to the measurement of the Electroencephalographic effects of desflu-rane anaesthesia. Anaesthesiology 2001; 95:30-35.

5.      White Pf , Tang J Romero G F ,wender RH, Naures R Sloninsky  A .et al .A comparison of state and response  entropy verus bispectral indexvalues duringthe perioperative period .Anaesthesia analgesia 2006 102 160 -7.

6.      H.viertio –Oja, V.Maja,M.Sarkela. Descr-iption of the entropy TMas applied in the Datex omeda S/5 Entropy module . Acta Anaesthesiol  Scand 2004 ; 48 674- 679.

7.      J W Dundee, FP robinson , JS Mc Collum, CC Patterson –Sensitivity to Propofol in the elderly . Anaesthesia 1986. 41 482 -485.

8.      DT Mangano perioperative cardiac morb-iddity. Anaesthesiology 1990 ;72 ;153 -54.

9.      HJ Priebe . The aged cardiovascular risk patient .Br J 2000;85 ; 763-778.

10.  W.Riad, M.Schrebiber,AB Saeed.  Mon-itoring with EEG entropydecrease propofol requirement and maintains cardiovascular stability during binduction of anaesthesia in elderly patients. European journal of anaesthesiology volume 24issue 8 2007 pp684-688.

11.  Anne Vakkuri ,Yli-Hankala, Rolf sandin et.al Spectral entropy monitoring is associated with reduced propofoluse and faster recovery in propofol –nitrous oxide-alfentanil anaesthesia . Anaesthesiology 2005;105:274-9.

12.  A Schultz,UGroven, I Zabder , A beger, M siedenberg, B Schultz. Age releated effects in the EEG during propofol anaesthesia. Acta Anaesthesiol Scand 2004   48 27-34;

13.  Anne Vakkuri, Yli-Hankala, P Talija . Time –frequency balanced entropy as measure of anaesthetic drug effect in  central nervous system during sevoflurane, propofol and thiopental anesthesia. Acta Anaesthesiol Scand 2004   48 145-153;

14.  Gunter N, Schmidt , Petra Bischoff . comparative evaluvation of Datex –Omeda S/5 entropy module and the Bispectral index monitor during propofol-remife-ntanil anesthesia. Anaesthesiology 2004; 101:1283-90.

15.  Anderson, R. and Jakobsson, J. Entropy of EEG during anaesthetic induction: a comparative study with propofol or nitrous oxide as sole agent. Br J Anaesth. 9(2), 167-70 (2004).

16.  Valjus M. et al. Response Entropy is not more sensitive than State Entropy in distinguishing the use of esmolol instead of remifentanil in patients undergoing gynaecological laparoscopy. Acta Anesthesiologica Scandinavica 50(1), 32-39 (Jan 2006)

17.  Wheeler P. et al. Response Entropy incre-ases during painful stimulation. Journal of Neurosurgical Anesthesiology 17(2),(April 2005)

18.  Takamatsu K. et al. Entropy indices vs the Bispectral Index for estimating nocice-ption during sevoflurane anesthesia. Br J Anaesth. 96(5), 620-626 (May 2006).

Corresponding Author

Dr Mohamed Zuhail  K.P

Junior Resident, Government Medical College, Trivandrum