Title: Direct detection of Left Ventricular Diastolic Dysfunction by Phase image analysis in Gated Thallium SPECT Scan

Authors: Dr V.Sivasubramaniyan, Dr K.Venkataramaniah

 DOI:  http://dx.doi.org/10.18535/jmscr/v4i7.09

Abstract

Aim: The evaluation and differentiation of Left Ventricular Diastolic Dysfunction  has a vital role in the management of heart failure patients. Currently the diastolic dysfunction is inferred from the E and A wave changes occurring in m-mode echocardiographic changes at the mitral orifice mostly. In the gated myocardial perfusion imaging from the time volume curve the Peak Flow Rate and Time to Peak Flow rate are derived and assessed for the presence and extent of diastolic dysfunction. All these parameters represent the changes that are occurring due to the underlying diastolic dysfunction in the left ventricular muscle mass. For the first time this study aims to highlight the diagnosis of Left Ventricular Diastolic Dysfunction by the visual Phase image analysis in Gated Thallium SPECT Scan. The presence of in-homogenous, irregular and insufficient tracer accumulation in the Diastolic phase images with the normal and homogenous tracer distribution in the Systolic Phase images is proposed to indicate the diastolic dysfunction. It also thrives to quantitate the changes observed by calculating the S/D ratio by dividing the Systolic Counts by the diastolic counts obtained from the raw phase images. It is correlated with echocardiographic stages of the Diastolic Dysfunction.

Materials and Methods: This study consists of 75 Males in the age group of 28 to 63 years with mean age of 47.9 +/- 7.8 years and 25 Females in the age range of 32 to 55 years with mean age of 49 +/- 6.8 years. After exercising the patients on a bicycle ergometer using Bruce Protocol 2 mCi of Thallum-201 was injected intravenously Gated SPECT MPI were acquired using Siemens Dual Head E-Cam Gamma Camera. The analysis was done using GATED SPECT PERFUSION ANALYSIS Protocol. The S/D ratio was  calculated using the region ratio count protocol in the ICON software.

Results: The discordance between the Diastolic and systolic images were found in 98/100 (98%)-Image1,2. The Echocardiographic evidence of Diastolic dysfunction as classified into Grade II and grade III using E / A  ratio analysis was found in 87/100 (87%). The diabetes was seen in 16/100 (16%) and Hypertension was encountered in 63/100 (63%).  The S/D ratio was 1.27 +/- 0.32 in Grade IILVDD and 1.68 +/- 0.03 Grade III LVDD.

Conclusion: In conclusion for the first time the utility of direct visual individual phase image analysis in the detection of Left Ventricular Diastolic Dysfunction is highlighted. The Scintimetric Characterization of the same with the help of S/D ratio shown it to be different between stage II and stage III LVDD.

Keywords: Gated Thallium SPECT, Left Ventricular Diastolic Dysfunction, echocardiography, Scintimetric evaluation, S/D Ratio.

References

    

1.      Recommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography -Sherif F. Nagueh, MD, Chair†, Christopher P. Appleton, MD†, Thierry C. Gillebert, MD*, Paolo N. Marino, MD*, Jae K. Oh, MD†, Otto A. Smiseth, MD, PhD*, Alan D. Waggoner, MHS†, Frank A. Flachskampf, MD, Co-Chair*, Patricia A. Pellikka, MD†, and Arturo Evangelisa, MD* Houston, Texas; Phoenix, Arizona; Ghent, Belgium; Novara, Italy; Rochester, Minnesota; Oslo, Norway; St. Louis, Missouri; European Journal of Echocardiography (2009) 10, 165–193

2.      A Guideline Protocol for the Echocardiographic assessment of Diastolic Dysfunction D rThomas Mathew (leadauthor) Dr Rick Steeds, Chair Dr Richard Jones Dr Prathap Kanagala Dr Guy Lloyd Dr Daniel Knight Dr KevinO' Gallagher Dr David Oxborough Dr Bushra Rana Dr Liam Ring Julie Sandoval Gill Whart on Dr Richard Wheeler Published November2013

3.      Evaluation of Left Ventricular Diastolic Function by Echocardiography  Juan Lacalzada et al.* Hospital Universitario de Canarias, La Laguna, Santa Cruz de Tenerife  Chapter 6, Establishing Better Standards of Care in Doppler Echocardiography, Computed Tomography and Nuclear Cardiology Edited by Dr. Richard M. Fleming ,2011.

4.      Gated SPECT with  Tc99m SESTAMIBI   for  assessment  of  Myocardial Perfusion  abnormalities, Morgan M.G., Mannting.F et.al  JNM 1993:21;13

5.      Comparison  between End Diastolic and  the  Summed images  of  Gated Tc99m MIBI  SPECT  in  the  detection  of  C.A.D in women -Raymond Taillefer, E.GordonDupey et.al  JNC, March/April- 1999

6.      Left  Ventricular Ejection  fraction assessed  from  Gated  Tc99m sestamibi  SPECT – Depuey.E.G, Nicholas K et al  JNM, 1993 : 34 :

7.      Role of Gated SPECT Myocardial Perfusion Imaging in the Evaluation of Diastolic Dysfunction of the Heart V. Sivasubramaniyan , P. K. Dash, V. R. Iyer, R. D. Prasad,  N. Purantharan. Oral Paper  Presentation Session 1 (Parallel) (CardioVascular System) Abstracts of SNMICON 2003.

8.      Left ventricular systolic/diastolic function evaluated by quantitative ECG-gated SPECT: comparison with echocardio-graphy and plasma BNP analysis Ichiro NAKAE,*Shinro MATSUO,* Terue KOH,* Kenichi MITSUNAMI** and Minoru HORIE* Annals of Nuclear Medicine Vol. 19, No. 6, 447–454, 2005.

9.      Assessment of Diastolic Function Using 16Frame 99mTc-Sestamibi Gated Myocardial Perfusion SPECT: Normal Values CigdemAkincioglu, MD1; Daniel S. Berman, MD1,2; Hidetaka Nishina, MD1; Paul B. Kavanagh, PhD1; Piotr J. Slomka, PhD1,2; Aiden Abidov, MD1; Sean Hayes, MD1; John D. Friedman, MD1,2; and Guido Germano, PhD1,2 J Nucl Med 2005; 46:1102–1108

10.  Assessment of Diastolic Heart Function – Experience with 16-gated Myocardial Perfusion SPECT RD Lele, KarunaLuthra, Yogini Sawant  JAPI • VOL. 56 • 763-767, OCTOBER 2008.

Corresponding Author

Dr V.Sivasubramaniyan

Doctoral Research Scholar

Dept of Physics, Sri Sathya Sai Institute of Higher Learning, Vidhyagiri,

Prasanthinilayam, Anantapur Dist. A.P 515134