Title: IsoPort- Pressure Differential Isolation Chamber Model for COVID-19 Patients

Authors: Mr. Ishan Gosavi, Dr Pratigya Mathur, Dr Amita Mathur

 DOI: https://dx.doi.org/10.18535/jmscr/v9i11.14

Abstract

The COVID-19 pandemic has made a huge impact on the healthcare scenario of the world. Due to its easy transmissibility, it has affected a majority of the population in a short time. Healthcare staff like nurses and doctors are at an even higher risk of infection because of their prolonged and repetitive interaction with patients. Isolation chambers can be an integral part of Vital care Units and Intensive Care Units (ICUs). Viral & bacterial matter can be present on surfaces of objects in regular use. A negative pressure environment can drastically curb the spread of viral matter in air. In this study, we have proposed a double-door isolation room model with air pressure differential control to prevent spread of the virus to the outside world. Our model aims to contain the viral air and eliminate airborne pathogens using High Efficiency Particulate Air (HEPA) filters and Ultraviolet (UV) light, along with antimicrobial surface coatings. The isolation chamber has prefabricated panels for short installation time, and are made with low-cost materials.

Keywords: COVID-19, Quarantine, Pressure Differential, Isolation Chamber, Air Purification, Antimicrobial.

References

  1. Otto SP, Day T, Arino J, Colijn C, Dushoff J, Li M, Mechai S, Van Domselaar G, Wu J, Earn DJD, Ogden NH, The origins and potential future of SARS-CoV-2 variants of concern in the evolving COVID-19 pandemic, Current Biology (2021), doi: https://doi.org/10.1016/j.cub.2021.06.049
  2. Chiranjib Chakraborty, Brain, Behavior, and Immunity, https://doi.org/10.1016/j.bbi.2021.05.018
  3. Hussin A. Rothan, Siddappa N. Byrareddy, The epidemiology and pathogenesis of coronavirus disease (COVID-19) outbreak, Journal of Autoimmunity, Volume 109, 2020, 102433, ISSN 0896-8411, https://doi.org/10.1016/j.jaut.2020.102433.
  4. Richardson ET, Morrow CD, Kalil DB, Bekker L-G, Wood R (2014) Shared Air: A Renewed Focus on Ventilation for the Prevention of Tuberculosis Transmission. PLoS ONE 9(5): e96334. doi: doi.org/10.1371/journal.pone.0096334
  5. Javier Cubillos*, Jill Querney, Adam Rankin, John Moore and Kevin Armstrong, A multipurpose portable negative air flow isolation chamber for aerosol-generating procedures during the COVID-19 pandemic, 2020 British Journal of Anaesthesia, Elsevier. Doi: https://doi.org/10.1016/j.bja.2020.04.059
  6. Jie Liua,1, Jingwen Liub,1, Zheng Hea,1, Zhicong Yangc, Jun Yuanc, Haoying Wua, Pingting Zhub, Xuesong Fud, Yunwan Lina, Ying Zhangb, Zhengyang Zhaoa, Shiyu Hea, Xiaowei Mae, Duration of SARS-CoV-2 positive in quarantine room environments: A perspective analysis, International Journal of Infectious Diseases 2020, Elsevier. https://doi.org/10.1016/j.ijid.2021.02.025
  7. Amir Ben-Shmuel 1, Tal Brosh-Nissimov, Itai Glinert, Elad Bar-David, Assa Sittner, Reut Poni, Regev Cohen, Hagit Achdout, Hadas Tamir, Yfat Yahalom-Ronen, Boaz Politi, Sharon Melamed, Einat Vitner, Lilach Cherry, Ofir Israeli, Adi Beth-Din , Nir Paran , Tomer Israely , Shmuel Yitzhaki, Haim Levy, ShayWeiss, Clinical Microbiology and Infection 2020, https://doi.org/10.1016/j.cmi.2020.09.004
  8. Noah J. Adams, MS, David L. Johnson, PhD, Robert A. Lynch, The effect of pressure differential and care provider movement on airborne infectious isolation room containment effectiveness, American Journal of Infection Control, 2010. https://doi.org/10.1016/j.ajic.2010.05.025
  9. Can J Anesth/J Can Anesth (2020) 67:568–576 https://doi.org/10.1007/s12630-020-01591-x

Corresponding Author

Mr. Ishan Gosavi

Department of Biomedical Engineering, Manipal Institute of Technology, Manipal, Karnataka