Title: Indications for uses of Homografts in Cardiac Patients at Sri Jayadeva Institute of Cardiac Sciences & Research and Their Follow Up

Authors: Koneru Khatnani Lata, Gupta Animesh, Bhat P.S. Seetharam

 DOI: https://dx.doi.org/10.18535/jmscr/v6i12.36

Abstract

Aims and Objectives: To evaluate the indications for uses of homografts in cardiac patients at srijayadeva institute of cardiac sciences & research and their follow up.

Methodology: Patients who received homografts in last two years (2012 to 2014) were included in this study. Homografts used  in the  study  group,  were  processed,  preserved  and thawed according to  protocols at our  institute’s  tissue valve bank. Prospective data was collected for all cases from 1.8.2012 to 31.7.2014 in all surgical units at Sri jayadeva institute of cardiac sciences and research Bangalore and followed up postoperatively for evaluation by clinical and echographic assessment for 6 months of duration. Homograft heart valves were retrieved from non beating heart donors, usually from cadavers during postmartum. Surgeons collected the heart using aseptic precaution, with sterile instruments. A piece of tissue from aorta and pulmonary artery were collected for culture into sterile container. Heart with great vessels transported in sterile double bags over ice from mortuary to our institute’s homograft valve bank. Heart was kept immersed in “Hank’s balanced salt solution” (HBSS) with antibiotic at 40 C, till dissection. Dissection of valve and conduit was done at earliest possible time. Homografts were kept moist during dissection by irrigation with HBSS. The coronary arteries were ligated and cut. Each valve was kept in 200 ml of HBSS with antibiotics and incubated for 72 hours at 40 C. The valves were transferred into fresh HBSS with antibiotic solution .After 72 hrs of sterilisation homograft valves were prepared for freezing, under sterile conditions. Aortic and pulmonary valve were packed separately in cold HBSS (90 ml) and 10 ml of DMSO (dimethyl sulphoxide) solution. After the freezing cycle for 11/hours the valves were stored in vapour phase of liquid nitrogen between - 120 0 C to  – 1800 C.The required valve was sent to operation theatre in cryo shipper maintaining the temperature below - 1000C.The fast thawing procedure was used. Outer cover of cryobag was cut open and inner cover was handed over to the scrub nurse. The valve was rinsed for 5 to 10 minutes with sterile water at 400 C. After that second and first bags were cut open and valve transferred into HBSS with DMSO 5% Solution for 5 min rinse time, followed by two rinses in plain HBSS.

Results: Total of 23 patients had received homograft, from 1.8.2012 to 31.8.2014 at our institute. 3 patients were died in perioperative period, hence excluded from the study.

Out of 20 live patients,13 (65%) were males and 7 (35%) female. The disease distribution was 17 (85%) cases out of 20 live patients were operated for a congenital disease (including bicuspid aortic valve). Rest 3(15%) cases were operated for rheumatic and degenerative heart diseases.3 out of the 23 patients died in our study. Two due to low cardiac output, in immediate perioperative period  (< 48 hrs ) and one due to renal dysfunction followed by Multi organ dysfunction (MODS) in late postoperative period ( at 45 days). These patients were excluded from the statistical analysis pertaining to valve dysfunction. Pulmonary homografts were used in 13 (65%) patients and aortic in the other 7 (35%) patients with size ranging from 18- 24 mm (mean – 20.45 mm). Mean size of aortic homografts used is 19 mm while that of pulmonary homografts was 21.23 mm. Pulmonary homografts were mainly used in pulmonary circulation (10 cases). Only in 3 cases they were used in aortic position. Aortic homografts were used in both aortic (3 cases) and pulmonary position (4 cases).Most (12) of the homografts used (60%) were cryopreserved for a period of less than 3 months. 25% (5) were preserved for 3-6 months and 15% (3)were older than that (>6 months). Of the 20 patients, 3 had homograft valve dysfunction in the post operative period- 2 were associated with homograft valvar regurgitation and 1 with homograft valvar stenosis (increased gradient). All 3 patients presenting with complications had homografts which were cryopreserved for less than 3 months with valve sizes 22-24 mm. Homograft pulmonary valve was used in all 3 cases, one in pulmonary and two in aortic position. Hence cryopreservation time, for implanted homografts, is not significantly associated with homograft dysfunction. Also, position of implanted pulmonary homograft (aortic / pulmonary) was statistically analysed in relation to homograft dysfunction using chi square test. Hence pulmonary homografts used in aortic position were related to significantly higher homograft dysfunction rate. In case of aortic homografts , 3 were used in aortic position and 4 in pulmonary position. However, none of these patients, developed homograft dysfunction/ complications. Probably, a larger series of patients or longer follow period is required to analyse the same.

Conclusion: Cryopreservation time was not significantly associated with homograft dysfunction. The use of pulmonary homografts in aortic position was associated with significantly higher complication and homograft dysfunction rate. The homograft valve is the best substitute and suited to Indian population. In cases of endocarditis of the native or mechanical prosthetic valve in the aortic position with coexisting abscesses of the ascending aorta, the implantation of a homograft is lifesaving. Logical use of homografts in adult and paediatric cardiac surgery when indicated with the proper surgical technique ensures a very good postoperative result and an excellent quality of life for the patient.

References

  1. Murray G. Homologous aortic valve segment transplants as surgical treatment for non-aortic and mitral insufficiency. Angiology. 1956;7:446–471
  2. Homograft replacement of the aortic valve. ROSSDN Lancet. 1962 Sep 8; 2(7254):487
  3. Barratt-Boyes BG: Homograft aortic valve replacement in aortic incompetence and stenosis. Thorax 1964; 19: 131-135.
  4. Malm JR Bowman FO, Harris PD, Kovalik ATW: An evaluation of aortic homografts sterilized by electron-beam energy. J Thorac Cardiovasc Surg 1967; 54: 471-475.
  5. Barratt-Boyes BG, Roche AHG, Whitlock RML: Six year review of the results of freehand aortic valve replacement using an antibiotic sterilized homograft valve. Circulation 1977; 55: 353-361.
  6. O’Brien MF, Stafford EG, Gardner MAH, et al: A comparison of aortic valve replacement with viable cryopreserved and fresh allograft valves, with a note on chromosomal studies. J Thorac Cardiovasc Surg 1987; 94: 812-823
  7. Homograft reconstruction of the aortic root for endocarditis with periannular abscess: a 17-year study. Yankah AC, Pasic M, Klose H, Siniawski H, Weng Y, Hetzer R Eur J Cardiothorac Surg. 2005 Jul; 28(1):69-75.
  8. Gulbins H, Anderson I, Kilian E, et al. Five years experience with mitral valve homografts. Thorac Cardiovasc Surg 2002; 50: 223-229
  9. Carr-White GS, Kilner PJ, Hon JK, et al. Incidence, location, pathology and significance of pulmonary homograft stenosis after the Ross operation. Circulation 2001; 104:I16-20.
  10. Oury JH, Angel WW, Eddy AC, Cleveland JC: Pulmonary autograft – past, present and future. J Heart Valve Dis 1993;2: 365-375.
  11. Doty JR, Salazar JD, Liddicoat JR, Flores JH, Doty DB: Aortic valve replacement with cryopreserved aortic allograft: ten-year experience. J ThoracCardiovascSurg 1998; 115: 371-379.
  12. Vogt PR, von Segesser LK, Jenni R, Niederhauser U, Genoni M, Kunzli A, et al: Emergency surgery for acute infective aortic valve endocarditis: performance of cryopreserved homografts and mode of failure. Eur J Cardiothorac Surg 1997; 11: 53-61.
  13. Dacey LJ: Pulmonary homografts: current status. Curr Opin Cardiol 2000; 15: 86-90.
  14. Koolbergen DR, Hazekamp MG, de Heer E, et al: Structural degeneration of pulmonary homografts used as aortic valve substitute underlines early graft failure. Eur J CardiothoracSurg 2002; 22: 802-807.
  15. Choudhary SK, Saxena A, Dubey B, Kumar AS: Pulmonary homograft: should it be used in the aortic position? J ThoracCardiovascSurg 2000; 120: 148-155
  16. Vesely I, Casarotto DC, Gerosa G: Mechanics of cryopreserved aortic and pulmonary homograft. J Heart Valve Dis 2000; 9: 27-37.
  17. Naegele H, Bohlmann M, Doring V, Kalmar P, Rodiger W: Results of aortic valve replacement with pulmonary and aortic homografts. J Heart Valve Dis 2000; 9: 215-220
  18. Raanani E, Yau TM, David TE, Dellgren G, Sonnenberg BD, Omran A: Risk factors for late pulmonary homograft stenosis after the Ross procedure. Ann ThoracSurg 2000; 70:1953-1957.
  19. Ross DN: Reflections on the pulmonary autograft. J Heart Valve Dis 1993; 2: 363-364.
  20. Selthilnathan V, Treasure T, Grunkemeier G, Starr A. Heart valves: which is the best choice? CardiovascSurg 1999; 7: 393-397.
  21. Simon P, Kasimir MT, Seebacher G, et al. Early failure of tissue engineered porcine heart valve Synergraft in pediatric patients. Eur J Cardiothorac Surg. 2003; 23: 1002-1006.
  22. Cebotari S, Mertsching H, Kallenbach K, et al. Construction of autologous human heart valved based on an acellular allograft matrix. Circulation 2002; 106; I63-I68.
  23. Zehr KJ, Yagubyan M, Connolly HM, et al. Aortic root replacement with a novel decellularized cryopreserved aortic homograft: Postoperative immunore-activity and early results. J Thorac Cardiovasc Surg. 2005; 130: 1010-1015.
  24. Hopkins RA, Jones AL, Wolfinbarger L, et al. Decellularization reduces calcification while improving both durability and 1-year functional results of pulmonary homograft valves in juvenile sheep. J Thorac Cardiovasc Surg. 2009; 137: 907-913.
  25. da Costa FD, Costa AC, Prestes R, et al. The early and midterm function of decellularized aortic valve allografts.Ann Thorac Surg. 2010; 90: 1854-60.
  26. Brown JW, Ruzmetov M, Eltayeb O, et al. Performance of Synergraft decellularized pulmonary homograft in patients undergoing a Ross procedure. Ann Thorac Surgery 2011; 91: 416-423.
  27. Elkins RC, Goldstein S, Hewitt CW, et al. Recellularization of heart valve grafts by a process of adaptive remodeling. Semin Thorac Cardiovasc Surg. 2001; 13: 87-92

Corresponding Author

Koneru Khatnani Lata

1Postgraduate Resident, Department of CTVS, SJIC&R, Bangalore – Karanataka