Title: Arthroscopic Reduction of Tibial Spine Avulsion using Transosseous Suture Technique Using Banana Laso: Technical Note

Authors: Dr Bhargav A. Desai, Dr Neel M.Bhavsar

 DOI:  https://dx.doi.org/10.18535/jmscr/v5i11.156

Abstract

The intra-articular portion of the upper tibial surface, called tibial eminence, consists of two spines: medial and lateral. The anterior cruciate ligamentis attached to the medial spine, whereas lateral spine has no attachment to any other structure.4 Tibial spine avulsion fractures (intercondylar eminence fractures) are most commonly faced in young patients between 8 and 14 years of age.1,2 Though such fractures in paediatric patients are rare injuries, they account for 14% of all anterior cruciate ligament (ACL) injuries in the same age group.3  The mechanism of injury is hyperextension of the knee with simultaneous rotation of the knee on the tibia, as may happen while falling off a bicycle, playing soccer or participating in other forceful sports related activities. Significant tension is put on the ACL, while doing hyperextension of knee.5 As the ACL originates on the lateral femoral condyle and inserts onto the anterior tibial spine, The forceful hyperextention results in an avulsion fracture of the tibial attachment site and this also leads to weakness in the cruciate ligament. The bone fails before the ligaments as per their elastic property and, hence, these fractures are common in children than in adults. The tibial spine fractures are classified [Meyer and McKeever] into three types: type 1 fracture is undisplaced; type 2 is partially displaced or hinged; and type 3 is completely displaced or inverted and impossible to reduce because of the transverse meniscal ligament preventing seating of the fragment.6A type IV is also described by Zaricznyj7, which represents rotation and comminution of the fragments.

References

  1. Lubowitz JH, Elson WS, Guttmann D. Part II: Arthroscopic treatment of tibial plateau fractures: Intercondylareminence avulsion fractures. Arthroscopy 2005;21:86-92.
  2. Liao W, Li Z, Zhang H, Li J, Wang K, Yang Y. Arthroscopic fixation of tibial eminence fractures: A clinical comparativestudy of nonabsorbable sutures versus absorbable suture anchors. Arthroscopy 2016;32:1639-1650.
  3. Kendall NS, Hsu SYC, Chan KM. Fracture of the tibial spine in adults and children. J Bone Joint Surg Br 1992;74:848-852.
  4. Wiley JJ, Baxter MP. Tibial spine fractures in children. Clin Orthop Rel Res 1990 ; 255 : 54-60.
  5. Mann MA, Desy NM, Martineau PA. A new procedure for tibial spine avulsion fracture fixation. Knee Surg SportsTraumatol Arthrosc 2012;20:2395-2398.
  6. Meyers MH, McKeever FM.Fractures of the intercondylarmeminence of the tibia. J Bone Joint Surg 1970 ; 52A : 1677-1684.
  7. Zaricznyj B. Avulsion fractures of the tibial eminence : treatment by open reduction and pinning. J Bone Joint Surg1977 ; 59A : 1111-1114.
  8. Rockwood CA, Wilkins KE, Beaty JH. Fractures in children. Philadelphia: Lippincott-Raven 1996 : 1296-1298.
  9. Hwang MD, Piefer JW, Lubowitz JH. Anterior cruciate ligament tibial footprint anatomy: Systematic review ofthe 21st century literature. Arthroscopy 2012;28:728-734.
  10. Hunter RE, Willis JA. Arthroscopic fixation of avulsion fractures of the tibial eminence: technique and outcome. Arthroscopy 2004 ; 20 : 113-121.
  11. Ando T, Nishihara K.Arthroscopic internal fixation offractures of the intercondylar eminence of the tibia.Arthroscopy 1996 ; 12 : 616-622.
  12. Chen FH, Chen M, Ruan JW, Pan WW, Wang HB, Han JH. [Arthroscopic treatment of anteri¬or cruciate ligament avulsion fracture from the tibial eminence with reduction and suture combined with button plate fixation]. Zhongguo Gu Shang 2011; 24: 415-417.
  13. Hirschmann MT, Mayer RR, Kentsch A, Friederich NF. Physeal sparing arthroscopic fixation of displaced tibial eminence fractures: a new surgical technique. Knee Surg Sports Traumatol Arthrosc 2009; 17: 741-747.
  14. Vega JR, Irribarra LA, Baar AK, Iniguez M, Salgado M, Gana N. Arthroscopic fixation of displaced tibial eminence fractures: a new growth plate-sparing method. Arthroscopy 2008; 24: 1239-1243.
  15. Senekovic V, Veselko M. Anterograde ar¬throscopic fixation of avulsion fractures of the tibial eminence with a cannulated screw: five-year results. Arthroscopy 2003; 19: 54-61.
  16. Doral MN, Atay OA, Leblebicioglu G, Tetik O. Arthroscopic fixation of the fractures of the in¬tercondylar eminence via transquadricipital tendinous portal. Knee Surg Sports Traumatol Arthrosc 2001; 9: 346-349
  17. Huang TW, Hsu KY, Cheng CY, Chen LH, Wang CJ, Chan YS, Chen WJ. Arthroscopic suture fixation of tibial eminence avulsion fractures. Arthroscopy 2008; 24: 1232-1238
  18. Sawyer GA, Anderson BC, Paller D, Schiller J, Eberson CP, Hulstyn M. Biomechanical analy¬sis of suture bridge fixation for tibial eminence fractures. Arthroscopy 28: 1533-1539.
  19. Lafrance RM, Giordano B, Goldblatt J, Voloshin I, Maloney M. Pediatric tibial eminence frac¬tures: evaluation and management. J Am Acad Orthop Surg 2010; 18: 395-405.
  20. Seon JK, Park SJ, Lee KB, Gadikota HR, Kozanek M, Oh LS, Hariri S, Song EK. A clinical comparison of screw and suture fixation of an¬terior cruciate ligament tibial avulsion frac¬tures. Am J Sports Med 2009; 37: 2334-2339

Corresponding Author

Dr Bhargav A. Desai

3rd Year Resident Dept of Orthopedics, V.S. Hospital, Ahmedabad