Title: The Region of Interest in Determining the Proper Value of Full-Width at Half Maximum during Magnetic Resonance Spectroscopy

Authors: Yeti Kartikasari, Gatot Murti Wibowo, Darmini, Dwi Rochmayanti, Anita Nur Mayani

 DOI:  https://dx.doi.org/10.18535/jmscr/v5i8.197

Abstract

Background: MRS is an advanced examination of MRI producing a spectra that describe metabolite information of tissues. ROI setting becomes very important in generating the spectral diagnostic value called Full-Width at Half Maximum (FWHM). All collected FWHM data will assist physicians to determine the stage of brain tumors. In clinical applications, Radiographers select several ROIs in obtaining FWHM values without any particular benchmark which directly affects the accuracy of the brain tumor stage. 

Objective: The purpose of this study is to examine the FWHM profiles based on the ROI selections and to determine the effect of selected ROIs on to FWHM values.

Methods: This research is a quantitative study with an experimental approach. Data were collected by an expert Radiographer during 30 days in June 2016 at Department of Radiology, Siloam Hospital Kebon Jeruk Jakarta using a particular bottle phantom MRI 2000 ml. The phantom was scanned with 1.5 Tesla MRI scanner, from which various selection of the ROIs sized 20 mm, 25 mm, 30 mm, 35 mm and 40 mm; at the several positions.  The positions employed were the centre, 12 o'clock, 3 o'clock, 6 o'clock and 9 o'clock. The analysis was performed to define the adequate size of ROI generating an optimum FWHM values. Linear regression applied to conclude whether or not there is an influence of the ROI size in generating FWHM values.

Results: The results showed the optimum FWHM values of 12-20 were generated from the ROI size 20-30 mm at the center position. Regression analysis deemed significant (p-value <0.05) leading to a conclusion that the ROI size setting affects the FWHM values. The smaller the ROI size, FWHM value will decrease with higher homogeneity and vice versa.

Conclusion:  ROI size setting affects FWHM value, and optimum FWHM value is generated by ROI size of 20 – 30 mm at the center position.

Keywords: Magnetic Resonance Spectroscopy, Region of Interest, Full Width at Half Maximum,

References

  1. Bluml, Stefan., 2013. “MR Spectroscopy of Pediatric Brain Disorders” Springer. USA.
  2. Dick J. Drost, William R. Riddle., Agustus 2002, “Proton magnetic resonance spectroscopy in the brain: Report of AAPM MR Task Group #9". USA.
  3. Horská, Alena, Ph.D. and Peter B. Barker, D. Phil., Agustus 2011, “Imaging of Brain Tumors: MRS and Metabolic Imaging." Neuroimaging Clin N Am. http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2927327/.
  4. John, Hesselink R., MD, FACR, 2007, “Fundamentals of MRS." http://spinwarp.ucsd.edu/neuroweb/Text/mrs-TXT.htm.
  5. Knoll, Glenn F. "Radiation Detection, and Measurement." 3rdNew York; Hamilton; 2000.
  6. Miller, Janet Cochrane, D, Phil.; Uppot, Raul N, M.D., Juli 2012, "Magnetic Resonance Spectroscopy in the Brain." Massachusetts General Hospital Department of Radiology. Volume 10, Issue 7, http://www.massgeneral.org/imaging/news/radrounds/july_2012/.
  7. Sachin, Gujar K MD; dkk, September 2005, “Magnetic Resonance Spectroscopy."Journal of Neuro-Ophthalmology.Volume 25, Issue 3, http://journals.lww.com/jneuroophthalmology/Fulltext/2005/09000/Magnetic_Resonance_Spectroscopy_.15.aspx.
  8. September 2005. “MR Spectro-scopy Quick Guide”. Germany.
  9. Tsao, Connie M.D. 2008. "Basic MRI Physics."Wikidoc Harvard Medical School. USA.
  10. Upadhyay, MBBS, MRes and A D Waldman, Ph.D., FRCR., December 2011, "Convent-ional MRI evaluation of gliomas." Internati-onal Journal of Radiology, Radiation Onco-logy and all related science. Volume 84, Issue 2, http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3473894/.
  11. Westbrook, Catherine; Carolyn Kaut Roth and John Talbot.“MRI in Practice”.4thUSA: Blackwell Science. 2000.

Corresponding Author

Yeti Kartikasari

Email: This email address is being protected from spambots. You need JavaScript enabled to view it.