Title: Comparison and Agreement between Venous and Arterial Blood Gas Values for pH, pCO2, pO2, Bicarbonate and Oxygen Saturation in Patients with Acute Respiratory Illnesses

Authors: Shobhit Shah, Sudhir Chhabra, Moonish Agarwal, Chandramani Panjabi, Subhash Narang, Chaitanya Krishna N, Tejesh Krishna Ch

 DOI:  https://dx.doi.org/10.18535/jmscr/v5i3.123

Abstract

Arterial blood gas (ABG) analysis is routinely performed for sick patients but is fraught with complications, is painful, and is technically demanding. As there is a huge requirement of performing ABG analysis, an alternative to the arterial puncture would be quite helpful in this setting, and the current study was aimed to determine the extent of correlation of arterial and venous blood gas (VBG) analysis with a view to identifying whether the venous samples can be used as an alternative to arterial values in clinical management of patients presenting with various acute respiratory illness. This prospective observational study was conducted on 90 patients who presented with acute respiratory illness in in-patient Department of Medicine and Pulmonology, Mata Chanan Devi Hospital, after applying specific inclusion & exclusion criteria. Pregnant ladies, patients having age less than 20 years and those who were having respiratory symptoms due to non-respiratory causes were excluded from this study. Arterial sample was drawn via an arterial puncture into a heparinized syringe in all patients and at the same time, venous blood was also taken, without application of tourniquet via antecubital vein into another heparinized syringe. Venous and arterial blood samples were taken within 5-minutes of each other and in addition to this, the measurement of oxygen saturation (SpO2) was obtained from finger pulse oximeter. In order to access the agreement between values of two samples, the paired t-test and Pearson correlation coefficient was used. The mean age of the patient in the present study was 62.4 ± 14.75 years and gender distribution was 54 males and 36 females out of total 90 patients. After statistical evaluation, the present study shows minimal difference and good correlation between arterial and venous samples for the values of pH, bicarbonates, pCO2 ( r > 0.9 ). Although the correlation of pO2 measurement was fair  ( r = 0.615 ) , but there was good correlation between values of finger pulse oximeter and arterial oxygen saturation( r > 0.9 ).  Thus, venous blood may be a useful alternative to arterial blood during blood gas analysis in the management of patients with acute respiratory illnesses. However, further large scale studies are needed to accurately assess whether VBG analysis can always replace ABG analysis.

Keywords: Arterial blood gas analysis,venous blood gas analysis.

References

1.      Murray and Nadel’s Textbook of Respiratory Medicine. 5th ed. Philadelphia Pa : Saunders Elsevier; 2010: chap 7.

2.      Cecil medicine. 24th ed. Philadelphia , Pa : Saunders Elsevier; 2011: chap 120

3.      Mortensen J. Clinical sequelae from arterial needle puncture, cannulation, and incision. Circulation.1967;35:1118–23.

4.      Criscuolo C, Nipper G, Buchalter S. Reflex sympathetic dystrophy following arterial blood gas sampling in the Intensive Care setting. Chest. 1995;108:578–80.

5.      Effros RM, Swenson ER. Acid-base balance. In: Mason RJ, Broaddus CV, Martin TR, et al. Murray & Nadel's Textbook of Respiratory Medicine. 5th ed. Philadelphia, PA: Saunders Elsevier; 2010:chap 7.

6.      Kelly AM, Kyle E, McAlpine R. Venous pCO2 and pH can be used to screen for significant hypercarbia in emergency patients with acute respiratory disease. J Emerg Med. 2002;22:15–9.

7.      Malatesha G, Singh NK, Bharija A, Rehani B, Goel A. Comparison of arterial and venous pH, bicarbonate, pCO2 and pO2 in initial emergency department assessment. Emerg Med J.2007;24:569–71.

8.      Toftegaard M, Rees SE, Andreassen S. Correlation between acid-base parameters measured in arterial blood and venous blood sampled peripherally, from vena cavae superior, and from the pulmonary artery. Eur J Emerg Med. 2008;15:86–91.

9.      Kelly AM, McAlpine R, Kyle E. Venous pH can safely replace arterial pH in the initial evaluation of patients in the emergency department. Emerg Med J. 2001;18:340–2.

10.  Rees SE, Hansen A, Toftegaard M, Pedersen J, Kristiensen SR, Harving H. Converting venous acid-base and oxygen status to arterial in patients with lung disease. Eur Respir J. 2009;33:1141–7.

11.  Koul PA, Khan UH, Wani AA, Eachkoti R, et al.Comparison and agreement between venous and arterial gas analysis in cardiopulmonary patients in kashmir valley of indian subcontinent.Ann thorac med 2011;6:33-7.

12.  Richard Treger, Shahrjar Pirouz, Nader Kamangar and Dalila Corry. Agreement between Central Venous and Arterial Blood Gas Measurements in the Intensive Care Unit. Clin J Am Soc Nephrol. 2010 Mar; 5(3): 390–394.

13.  Middleton P, Kelly AM, Brown J, Robertson M. Agreement between arterial and central venous values for pH, bicarbonate, base excess, and lactate. Emerg Med J. 2006;23:622–4.

14.  Awasthi S, Rani R, Malviya D. Peripheral venous blood gas analysis: An alternative to arterial blood gas analysis for initial assessment and resuscitation in emergency and intensive care unit patients. Anesth Essays Res. 2013; 7:355–8.

Corresponding Author

Shobhit Shah

Department of Medicine and Pulmonology

Mata Chanan Devi Hospital, Janakpuri, New Delhi