Title: Outcome of Stainless Steel Proximal Femoral Nailing in Inter-Trochanteric Fractures of Femur

Authors: Nandakumar R, Ashish Kumar Jose, Krishnagopal R.

 DOI:  http://dx.doi.org/10.18535/jmscr/v3i11.15

Abstract

Inter-trochanteric fractures of the femur are commonly seen in the elderly. Surgical fixation of these fractures significantly reduces the morbidity and mortality in the elderly by avoiding complications arising out of prolonged bed rest. Several implants have been designed for the treatment of these fractures. In this study we analyzed the functional and radiological outcome in inter-trochanteric fractures fixed with stainless steel proximal femoral nail. We concluded that stainless steel proximal femoral nail is an ideal implant for the fixation of these fractures.

Key words: Inter-trochanteric fracture, Proximal femoral nail.

References

1.      Zuckerman JD, Skovron ML, Koval KJ, Aharonoff G, Frankel VH (1995) Postoperative complications and mortality associated with operative delay in older patients who have a fracture of the hip. J Bone Joint Surg [Am] 77:1551–1556.

2.      Albareda J, Laderiga A, Palanca D, et al. Complications and technical problems with gamma nail. Int Orthop. 1996;20:47- 50.

3.      Butt MS, Krikler SJ, Nafie S, Ali MS. Comparison of dynamic hip screw and gamma nail: a prospective, randomized, controlled trial. Injury. 1995;26:615-8.

4.      Boyd, H. B. & Griffin, L. L. (1949) Classification and treatment of trochante-ric fractures. Arch. Surg. 1949;58,853-866.

5.      Kyle RF, Gustilo RB, Premer RF. Analysis of six hundred and twenty-two intertrochanteric hip fractures. J Bone Joint Surg Am 1979;61:216–21.

6.      Pajarinen J, Lindahl J, Michelsson O, Savolainen V, Hirvensalo E: Pertrochanteric femoral fractures treated with a dynamic hip screw or a proximal femoral nail. A randomized study comparing postoperative rehabilitation. JBJS (Br) 2005; 87: 76-81.

7.      T. Morihara: “Proximal Femoral nail for treatment of trochantric femoral fractures” . Journal of Orthopaedic surgery 2007; 15(3): 273-7.

8.      N Muzaffar, A.R. Malik and A. Shilari. “A comparison between proximal femoral nail and locking compression plate-Dynamic hip screw devices in unstable intertoxhanteric fractures-Which is better?” Journal of orthopaedics vol-5, no 1, 2013,11-17.

Corresponding Author

Ashish Kumar Jose

Department of Orthopaedics,

Mahatma Gandhi Medical College & Research Institute, Pondicherry, India